TIGER Select handheld benzene detector – now with ION Science benzene pre-filter tube!

Benzene & Total Aromatic Compound (TAC) detection in one instrument

The Tiger Select is a revolutionary hand-held gas detector for the rapid and accurate detection of benzene and Total Aromatic Compounds (TACs).

Utilizing the high output ION Science 10.0 eV detection system, a reading for TACs is seen immediately on start-up. Should aromatics be detected, an ION Science benzene pre-filter tube can be easily attached to ensure fast detection and selective measurement of benzene.

Throughout the measurement process, Tiger Select continues to display real-time data, ensuring the final reading represents the full value of actual benzene present. Benzene concentrations are displayed down to parts-per-billion (ppb) levels, giving you accurate, reliable data you can count on.

Tiger Select is capable of providing 15-minute short-term exposure limits (STELs) and 8-hour time-weighted averages (TWAs) for total aromatic compounds (TACs). A 10.6 eV lamp can easily be installed for the detection of a wide range of VOCs.

In addition, the unique ION Science PID sensor incorporates both humidity resistant technology and anti-contamination design for extended operation in difficult working environments.

The Tiger Select benzene and total aromatic compound detector can also be used in standard Tiger operational mode without the use of a benzene pre-filter tube to deliver active indications of volatile organic compounds (VOCs), including benzene, at concentrations as low as 1 ppb benzene equivalent.

See our range of leading VOC detectors:

handheld benzene detector

Key Features

Best proven photoionization (PID) detection

  • PID independently verified as best performing on the market
  • Unrivaled sensitivity detects down to ppb levels
  • Selectively detects benzene with ION Science pre-filter tube
  • Continuous readings shown as max level reached
  • Built-in humidity resistance with no need to compensate
  • Anti-contamination design for extended field operation

Minimize downtime

  • Ready to use instantly with no complicated set-up
  • Large battery capacity gives several days of use
  • Fast charge capability gets you up and running quickly
  • Simple icon driven menu requires no user training
  • Fastest data download via true USB connection
  • Easily upgrade your instrument via the web 24/7

Ease of use

  • Self-explanatory software and calibration routine
  • Easy change sensor, electrode stack, and lamps
  • Large user-friendly keypad
  • Simple, one-handed operation

Low cost operation

  • Inexpensive parts and consumables
  • Five year warranty when instrument registered online
handheld benzene detector

What’s included

Tiger Select Premium Plus Kit details can be found below. For more information or prices please contact ION Science.

TIGER Select Kit:

  • Tiger Select instrument
  • Premium Plus Case
  • Rechargeable battery (Li-ion)*
  • Battery charger
  • Mains adaptor
  • Rubber boot
  • Benzene pre-filter tubes (Box 10)
  • Tiger Select manual
  • Tiger Select Quick Start Guide
  • Benzene pre-filter tube opener
  • Carbon filter assembly
  • PTFE filter discs
  • Removable tool for MiniPID stack
  • Sample cleaning compound
  • Lanyard (Wrist Strap)
  • Calibration adaptor
  • Sensor seal – coated
  • Gas Cylinder*
  • Gas Regulator*

*Please note, the Spare Battery, Gas Regulator and Gas Cylinder can be added to your Tiger Select Premium Plus Kit as additional spares.

Alternative case and kit options are available, please contact ION Science for more information.

Product downloads – ION Science


Product downloads - Ion ScienceFor all downloadable resources please click here

Brochures, Manual, Quick Start Guides, Software etc.

Technical Specification

Technical Specification

Value/Information

Resolution PPM model0.001 ppm (1 ppb) benzene in Tube mode     0.01 ppm in TAC mode    0.1 ppm in standard running mode:
Resolution PPB model0.001 ppm (1 ppb) benzene in Tube mode.    0.001 ppm in TAC modes.    0.001 ppm in standard running mode
Maximum Reading0 to 200 ppm benzene in tube mode, up to 20,000 ppm in TAC mode (gas dependent)
Response TimeT90 < 2 seconds in normal running and TAC mode
Accuracy± 10% display reading ± one digit benzene
Linearity± 5% display reading ± one digit
Response Time
120 seconds in Tube mode. Progressive indication of benzene breakthrough is displayed in real time
Intrinsically Safe ApprovalsII1GExiaIICT4Ga
Tamb = – 15 0C ≤Ta ≤+45 0C (with alkaline battery pack) ITS09ATEX26890X IECEx ITS 10.0036X
3193491 conforms to UL Std. 913, 61010-1 &
Certified to CAN/CSA Std. C22.2 No. 61010-1.
Class 1 Division 1. Approval for Groups A, B, C & D, T4
Battery LifeLi-ion: life up to 24 hours, charge time 6.5 hours
Alkaline: 3 x AA, typically 8.5 hours life
PID Lamps10.0eV Krypton PID lamp
Data Logging> 120,000 data log points including date and time stamp
CommunicationDirect USB 1.1
Calibration2 and 3 point calibration (via calibration kit accessory)
AlarmFlashing LED’s Amber (low alarm) Red (high alarm) Sounder 95 dBA at 300mm (12”) Vibration on alarm. Pre-programmed TWA and STEL*
Flow Rate>220 ml/min (150 cc/min flow alarm)
TemperatureOperating: -20 to 60 0C, -4 to 140 0F (non Intrinsically Safe)
Humidity: 0-99% RH (non condensing)
ProtectionDesigned to IP65 (heavy rain)
1180
EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A
Weight & Dimensions Instrument (probe fitted,no tube attached) Length:465xHeight:89xDepth:61 mm (18.3×3.5×2.4”) Standardcase Packed weight: 5kg (176oz)

Note: PhoCheck is a US registered trademark, no. 2880994, and UK registered trademark, no. 2212457. Fence Electrode Technology is produced by ION Science Ltd, and protected by U.S. Patent No. 7,046,012.. EP 1474681, other patents pending.

Downloads

Video Support

Video Support – Tiger Select handheld benzene detector

Product Testimonials

Tiger Select handheld benzene detector

Product Enquiries

If you would like a member of our team to discuss your needs and questions relating to this product, please click the enquire button below now.

Technical Support

If you already have this instrument and have a technical enquiry, please call us on the number below.

Accessories

The following accessories are available for the Tiger Select handheld benzene detector.
For further information or pricing please contact ION Science or your local Distributor.

Product Inquiry Form

Please complete the form below and a member of our team will contact you.

TITLE HERE